Description
SPECIFICATIONS
Brand Name: TATETS
Origin: Mainland China
Hign-concerned Chemical: None
DIY Supplies: Metalworking
Type: AL
Model Number: JYL0061
|
Product Description: Aluminum crucible (origin: China) ,Material: 99.99%Al ,Used temperature range: -150 ~ 650℃,(Packing:1set/100pcs ,Aluminum crucible include cover). TAS instrument chemical materials co., LTD., specializing in the production of sales, DTA, DSC differential scanning calorimeter differential thermal analyzer, TGA (thermogravimetric analyzer and other special thermal analyzer of alumina, zirconia, metal aluminum, the material such as platinum crucible. Crucible dimension for 2-100 - MM diameter, height 2.5-140 - MM of various specifications, the minimum wall thickness can reach 0.1-0.3 MM, more complete variety, all the year round in stock. This store sells crucible can be adapted in Lin Seth Linseis Germany, the United States, the United States TA PE, Germany Netzsch, Switzerland Mettler, France Setaram tara mu, Shimadzu from Shimadzu, Japan neo-confucianism Rigaku, Japan seiko SII, Germany brooke AXS companies such as production of thermal analysis instruments, and provide samples to figure processing customized service. For Beijing optical instrument factory, Shanghai balance instrument plant, the TA, Germany Netzsch, Switzerland Mettler supply instruments both at home and abroad, product quality by domestic famous universities and research institutes, sells in distant markets places such as Hong Kong and Taiwan, Europe and the United States, the Middle East. In order to ensure the sample with high efficiency of heat exchange between sensors, please choose high quality, suitable temperature range of the sample disc/crucible experiment, so as to achieve the best effect of experiment. 1. Stainless steel plate/crucible suitable temperature range for sample room temperature to 350 ℃ 2. Samples of aluminum plate/crucible suitable temperature range for room temperature to 600 ℃ 3. Alumina sample plate/crucible can use up to 1800 ℃ Thermal analysis sample plate/crucible's brief introduction: Aluminum crucible is introduced: 1. Aluminum sample plate and sample cover: suitable for non-volatile solid samples, such as polymer and drugs, often used for polymer, materials in thermoplastic and thermosetting polymer melting, crystallization and glass transition of research; Sample plate as the bayonet, but did not seal. 2. In order to avoid the sample plate/crucible and sample reaction can use inert sample plate/crucible, such as platinum rhodium plate/crucible sample. 3. Copper or platinum rhodium plate/sample crucible can act as a catalyst effect and also used in most of the material of the TGA analysis. 4. High pressure sample plate: the whole experiment sample in the sample set/sealed environment of crucible, restrain the volatilization of volatile substances; Sealed to prevent solvent evaporation or volatile reaction products included, to eliminate the interference of heat of vaporization. 5. High quality of the sample disc/crucible can help expand the application range of the DSC, using a large volume of sample plate/crucible into more samples can be used to measure the heating effect of the weak, want to get better resolution can be used to light, good thermal conductivity sample plate/crucible. Alumina crucible is introduced: Alumina crucible using high purity alumina powder as raw material, combined with modern advanced burning technology, specializing in the production of thermal analysis with alumina zirconia ceramic crucible, ensure the product is used in the following four characteristics, well meet the needs of all kinds of thermal analysis experiment. 1. High thermal conductivity, heat transfer between samples and crucible speed, to ensure that there is a very small difference in temperature between, uniform temperature distribution. 2. Structure stable performance, high purity powder with precision control of high temperature sintering process, the formation of dense, uniform micro crystal phase structure, to ensure that in use process not peak, with the analysis of the sample is not easy to physics and chemistry. 3. Ultra high temperature stability using temperature range, the highest working temperature can reach 1800 degrees. 4. High utilization rate of repeat: water or 10% hydrochloric acid washing, drying, can be repeated use, does not affect the result of the experiment.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||